Sign In | Join Free | My himfr.com
Home > Voltage Surge Suppressor >

Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

    Buy cheap Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v from wholesalers
     
    Buy cheap Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v from wholesalers
    • Buy cheap Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v from wholesalers
    • Buy cheap Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v from wholesalers
    • Buy cheap Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v from wholesalers
    • Buy cheap Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v from wholesalers

    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

    Ask Lasest Price
    Model Number : TS-230M5RM
    Brand Name : TSTLP
    Certification : CE Compliance
    Price : Negotiable if good quantity
    Delivery Time : Around 7 working days upon receipt of payment
    Payment Terms : 100% TT / LC / Western Union / MoneyGram / WeChat Transfer / Alipay / Wanda Money Transfer / Cash ahead
    Supply Ability : 2000 sets/month
    • Product Details
    • Company Profile

    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v

    24v / 48v / 60v / 120v / 220v / 230v Type 3 Transient Surge Suppressor


    TS-230M5RM Class III transient surge suppressor is designed as per IEC 61643-11 to install at LPZ 1-2 or higher as fine protection for electronic devices. e.g. icebox, air conditioner, photocopy, communication equipment, network equipment... various power supply system


    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v


    Relative 150Vdc / 600Vdc / 750Vdc / 1000V DC Surge Protection Device for photovolatic protection.

    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v


    • Type 3 Surge Protector Technical Data
    Model No.TS-230M5RMTS-120M5RMTS-60M5RMTS-48M2RMTS-24M2RM
    Normal a.c. Voltage Un230V120V60V48V24V
    Rated voltage (max.a.c. continuous voltage) Uc320V150V75V60V30V
    Rated voltage (max.d.c. continuous voltage) Uc320V150V75V60V30V
    Normal Current IL16A16A16A16A16A
    Nominal discharge current (8/20, L-N) In3 kA2.5 kA2.5 kA1 kA1 kA
    Nominal discharge current (8/20, L+N-PE) In5 kA5 kA5 kA2 kA2 kA
    Combination wave (L-N) Uoc6 kV6 kV6 kV2 kV2 kV
    Combination wave (L+N-PE) Uoc10 kV10 kV10 kV4 kV4 kV
    Voltage protection level(L-N) Up≤1.15 kV≤0.7 kV≤0.5 kV≤0.35 kV≤0.2 kV
    Voltage protection level(L+N-PE) Up≤1.5 kV≤1.1 kV≤0.85 kV≤0.85 kV≤0.85 kV
    Response time tA≤25ns (L-N); ≤100ns(L+N-PE)
    Max. back up fuse16A gL/gG
    Operating temperature range Tu-40°C...+80°C
    Short-circuit withstand capability at max.backup fuse6kArms
    Relative humidity:≤95% (25°C)
    Cross-sectional area0.5mm2 ~ 6mm2 solid / 4mm2 flexible
    Mounting on35mm2 DIN rail
    Enclosure materialRed thermoplastic, UL94-V0
    StandardsIEC 61643-11; GB 18802.1; YD/T 1235.1
    Type of remote signalling contactBreak contact
    Switching capacity UN/INAC:250V/0.5A DC:250V/0.1A,125V/0.2A,75V/0.5A
    Cross-sectional area for remote signalling contactMax. 1.5mm2 solid / flexible
    ComplianceCE (LVD, EMC)

    • Main Character
    1. Class 3 transient surge suppressor with LIGHT indications: Green - OK, red - Fault
    2. Single-phase surge protection and with disconnector
    3. Remote signalling connector for fault indication
    • INSTALLATION STEPS
    1. Mount the transient surge suppressor on 35 mm DIN rail.
    2. Connect conductors, the cross-sectional area of cable must be larger than 4mm2 . The withstand voltage value of cable is not smaller than AC500V; ensure wiring reliable.
    3. If Remote Alarm needed, it s/b connected signal lines to remote signal terminal 1 and 2 connected.
    4. After above, switch on the power supply and turn on the circuit breaker, if the transient surge suppressor’s indicator light displays green,this indicates the unit is operating normally.

    Regularly inspect the operating status, especially after lightning. Once the fuse upstream breaks, or the transient surge suppressor's indicator light displays red, electrician should check/replace the transient surge suppressor.


    • Installation Diagram

    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v


    • Real Type 3 Surge Protection Device Installation

    Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v


    PDF Catalog Download - TSTLP 24~230V Type 3 SPD.pd...


    Tag: transient surge suppressor

    Quality Type 3 Transient Surge Suppressor 24v / 48v / 60v / 120v / 220v / 230v for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: TS Lightning Protection Co.,Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)